Security Advisory — KNOB Attack Vulnerability
| Title | Security Advisory — KNOB Atack Vulnerability |
| Internal ID | SONOFFCVE-2026-001 |
| Release Date | 2/10/2026 |
| CVE ID | CVE-2019-9506 |
| Abstract |
The Bluetooth BR/EDR specification up to and including version 5.1 permits sufficiently low encryption key length and does not prevent an attacker from influencing the key length negotiation. This allows practical brute-force attacks (aka "KNOB") that can decrypt traffic and inject arbitrary ciphertext without the victim noticing. |
| Affected Product | SONOFF NSPanel Pro Smart Home Control Panel-120 Type |
| Affected Version | v4.2.3 and before |
| Impact | An unauthenticated, adjacent attacker can force two Bluetooth devices to use as low as 1 byte of entropy. This would make it easier for an attacker to brute force as it reduces the total number of possible keys to try, and would give them the ability to decrypt all of the traffic between the devices during that session. |
| Technical Details |
The attacker intercepts the LMP encryption key negotiation. The exploit sends an LMP_encryption_key_size_req = 0x01. The NSPanel Pro device responds with LMP Accept, accepting a 1-byte encryption key. The connection completes with downgraded encryption. The device does not enforce minimum 7–16 byte encryption keys, making it susceptible to KNOB. The resulting 8-bit key is brute-forced instantly, allowing full traffic decryption. |
| Resolution | Upgrade to firmware v4.4.0 and above |
| Source | This vulnerability was reported to the SONOFF Security Team by external security researcher Sanketh J. We sincerely thank him for reporting this problem to us. |